Tuning & Loading Meter Circuit

From Collins 30S-1 HF Amplifier
Revision as of 19:57, 6 July 2020 by Gordonp (talk | contribs) (Created page with "In operation, I could not obtain a useful meter-reading from the TUNING & LOADING meter position. Digging further, CR101A (a 1N34 diode) was completely shorted. Under this co...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

In operation, I could not obtain a useful meter-reading from the TUNING & LOADING meter position. Digging further, CR101A (a 1N34 diode) was completely shorted. Under this condition, the TUNE/LOAD meter gave about a 1/3-scale reading, with only a tiny response to adjusting Tune and Load controls. I tuned the amplifier for use by observing Screen Current.

I replaced both CR101A and CR101B with 1N5711 Schottky hot-carrier diodes. Capacitor C112 and resistor R105 both required adjusting (per 1976 mnaual, page 4-2, section 4.5). To adjust R105 safely, I pushed a foot of cable-jacket onto the shaft, then jammed a medium-length screwdriver into the other end of the cable-jacket - making a flexible adjuster which also kept my fingers out of the compartment.

With the change to a 4CX1500B tube, and the elevated screen-supply, I could not quite dial-in a "perfect" 0-reading on the meter, at resonance - there's no adjustment-travel left on either C112 or R105.

Satisfied that the circuit is now generally functional, I continue to tune by watching Screen Current, hitting 0mA at whatever power-level I use.


Back to Repair