Dealing with the Overheated and Cracked R232

From Collins 30S-1 HF Amplifier
Revision as of 20:29, 11 November 2020 by Gordonp (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Cooked broken r232.jpg

R232 broken into two pieces. Somewhere along the line, a previous repair has replaced the Collins 10-ohm 14W resistor with this small (2W???) resistor; it's overheated then cracked as a result.

The purpose of this resistor is to limit screen-supply (inrush) current, in the same manner as R222 and R223 do for the HV plate-supply.


30s 1 r232 tubular ceramic replacement.jpg

Awesome new 10-ohm 20W R232! This Ohmite replacement brings higher-dissipation, and solid mounting.

I wanted to mount R232 very solidly, so I opted for a tubular-ceramic resistor with mount-clips. I also moved to higher-dissipation capacity (20W) than Collins specified (14W), and I chose a new placement with improved air circulation and reduced heat-soak of nearby components - along the edge of the Relay Shelf.

Mounting hardware is all 18-8 stainless: #6-32 x 3/8 Phillips pan-head machine-screws, internal-tooth lockwashers and hex-nuts. On the outer (visible) edge of the Relay Shelf, I aligned the Phillips-head crosses :-)

In this location, and for other repairs, my wire of choice is either 22ga or 18ga (19 or 34 strands of 0.007 for maximum flexibility), with 3kV silicone insulation.