Operation: Difference between revisions
Jump to navigation
Jump to search
Line 7: | Line 7: | ||
=Dial Lights After Warm-Up= |
=Dial Lights After Warm-Up= |
||
The 30S-1 amplifier was designed with a 3-min delay before allowing High Voltage on the tube - the Eimac datasheet specifies at least this long. Mine is closer to 2-1/2 minutes, so I must pause before pushing the "ON" button. To let me know when this time-delay has completed, I re-wired my dial-lights to the DC circuit which is down-wind of the thermal delay-timer: |
The 30S-1 amplifier was designed with a 3-min delay before allowing High Voltage on the tube - the Eimac datasheet specifies at least this long. Mine is closer to 2-1/2 minutes, so I must pause before pushing the "ON" button. To let me know when this time-delay has completed, I re-wired my dial-lights to the DC circuit which is down-wind of the thermal delay-timer; the dial-lights will only turn on after the time-delay: |
||
* remove the hot lead from lamp socket DS201 |
* remove the hot lead from lamp socket DS201 |
||
* Add a new lead from DS201 to the white-red-orange-green wire at the rear of the HV "OFF" switch, S208 (either contact) |
* Add a new lead from DS201 to the white-red-orange-green wire at the rear of the HV "OFF" switch, S208 (either contact) |
Revision as of 13:49, 26 May 2020
Dayton Blower Sound Level
Here are a couple of sound-measurements, for context. I used the NIOSH iOS app:
- 30S-1 with Dayton 3,000rpm motor change: 59 dB(A) 1-meter directly in front
- Listening to HF Radio, SSB voice: 65 dB(A) for my preferred Sound Level
- My living-room is a blissful 36 dB(A)
Video showing Dayton Blower Start-up Sound
Dial Lights After Warm-Up
The 30S-1 amplifier was designed with a 3-min delay before allowing High Voltage on the tube - the Eimac datasheet specifies at least this long. Mine is closer to 2-1/2 minutes, so I must pause before pushing the "ON" button. To let me know when this time-delay has completed, I re-wired my dial-lights to the DC circuit which is down-wind of the thermal delay-timer; the dial-lights will only turn on after the time-delay:
- remove the hot lead from lamp socket DS201
- Add a new lead from DS201 to the white-red-orange-green wire at the rear of the HV "OFF" switch, S208 (either contact)
Here is a 10-second video clip showing the dial-lights illuminating, after the time-delay: